Phau Ntawv Qhia

4|Page
SOLENOID MODULE
MODEL # MOD-SOL1 (in 110V, NEMA 5-15 plug)
MOD-SOL2 (in 230V, CEE 7/7 plug)
MOD-SOL3 (in 230V, BS 1363 plug)
MOD-SOL4 (in 230V, AS/NZS 3112 plug)
TheSolenoidModuleisdesignedtoconnectaNORMALLY
CLOSEDlinevoltagesolenoidvalvetothecontroller.Itis
possibletousea12Vor24Vnormallyclosedsolenoidby
replacingtheACpowercord.Notethatthemaximumcontact
rangis240VAC(50-60Hz)/30VDC/2A.
LOCATION
Step 1) Findasuitablelocaononthewallforthesolenoid
module. The module must be installed close enough to the
controller,ortheUVsensortobeabletopluginthemale
IEP connector. The module must also be installed close
enough to the actual solenoid valve and this distance will
bedependentonthecordlengthoftheparcularsolenoid
valve that is used.
Step 2)Pickalocaonforthesolenoidvalveandinstallas
perthemanufacturersdirecons.Thesolenoidmodule
requiresbareleadsforconnecontoterminalblocks,so
ifthesolenoidcablehasaplugaached,removetheplug
andstripthewirestoasuitablelength.
INSTALLATION
Step 1) MakesurethesolenoidvalvecableisNOTpluggedintotheelectricaloutlet.Insert
thesolenoidvalvecablethroughthecenterholeofthemiddlestrainrelief.Connectthethree
electricalwirestotheterminalblockthatismarked“SOLENOID”(seeFig.2).Connectthe
groundwireintheposionmarked“GND”,thelinevoltagewireintheposionmarked“L1”
andtheneutralwireintheposionmarked“N”.Typicalwirecolourconguraonsaremarked
directlyonthecircuitboardtotheleoftheSOLENOIDterminalblocktoaidinthisprocess
(seeFig.3)Ifyouareunsureofthecorrectwiringconguraonforyouparcularsolenoid
valve,pleasecontactanapprovedelectricalcontractor.Onceallthelinevoltageconnecons
havebeenmade,ghtenthestrainreliefnuttosecurethecabletothesolenoidmodule.
Figure 3
WiringColourGuide
Figure 2
SolenoidWireInstallaon
Figure 1
Secure
module to
wall with
screws