User Manual

4|Page
Install Procedure – NPT Adapters
1. Place one of the union nuts over an NPT tail piece
• Make sure to use plumbers tape on the NPT thread
2. Install Flowmeter adapter to the piping on the UV chamber’s Inlet.
• Flowmeter must be installed horizontally.
Place the rubber washer inside of the union nut and aach the Flowmeter to the union nut
• The ow direcon arrows MUST poinng to the inlet of the UV chamber.
• The union nut only needs to be hand ghtened.
4. Place the other union nut over the other NPT tail piece, place the rubber washer inside of the union nut
and aach the adapter to the other side of the Flowmeter
• The union nut only needs to be hand ghtened.
5. Prepare/measure the required piping to install to the NPT adapter
Make sure that the length of pipe on the inlet to the Flowmeter is 10 mes the diameter of
the pipe. Refer to specicaons for lengths.
6. Remove the Flowmeter, and install the piping to the NPT adapter.
Do not apply any heat to the piping or sweat adapters with the Flowmeter installed, this
could potenally damage the rubber washer and Flowmeter creang a major leak.
7. Install the piping to the NPT adapter
• Make sure to use plumbers’ tape on the NPT thread
8. Install the Flowmeter back to the union nuts of the NPT adapters.
• The ow direcon arrows MUST be poinng to the inlet of the UV chamber.
• The union nut only needs to be hand ghtened, allows for easy maintenance.
Module Installaon
Once the Flowmeter and the UV system has been plumbed:
Step 1) Power o the BLACKCOMB or BLACKCOMB-HO controller.
Step 2) Plug in the AC/DC wall adapter (5V Max) into the power port on the Flowmeter.
Step 3) Plug the male plug of the Flowmeter into the IEP (Innite Expandability Port) on the controller, or
into any other LUMINOR module that contains an IEP (sensor, 4-20mA module, solenoid module,
etc).
Step 4) Power on the system and the controller will detect and inialize the Flowmeter module during the
start-up sequence.
Sensor IEP
Installaon
IEP
connecon
BLACKCOMB
Controller
BLACKCOMB-HO
Controller
IEP
connecon
IEP
connecon