Instructions

9|Page
Installaon
Step 1: The reactor can be installed either horizontally or
vercally using the clamps provided. Vercal installaon is the
preferred method with the inlet at the boom (lamp connecon
at the top) as it allows any air that may be in the lines to be easily
purged from the system.
Step 2: The use of a by-pass assembly is recommended as it will
allow you to isolate the UV reactor. This will allow for easier access
in case maintenance is required (See Figure 4).
Step 3: Fasten chamber clamps to wall with screws provided.
The screws must anchor securely into solid wood, concrete, or steel
structure for adequate strength. Do not aempt to secure screws
into drywall (Figure 3a). Install Chamber into clamps (Figure 3b).
Step 4: For water supplies where the maximum ow rate is
unknown, a ow restrictor is recommended so that the rated ow
of your parcular BLACKCOMB system is not exceeded. The ow
restrictor should be installed on the inlet port of the reactor.
Step 5: It is recommended to have a licensed plumber connect
the UV reactor to the water supply and may be a requirement
depending on where you are located.
leave at least
an addional
reactor length
to facilitate
lamp and
sleeve removal
Figure 2. Lamp
Removal Spacing
Figure 3a. Fasten
clamps to wall
Figure 3b. Install
chamber into clamps
Figure 4. By-pass
assembly
Note: Installaon of your BLACKCOMB disinfecon
**
systems shall comply with applicable provincial/
state & local regulaons.