Instructions

5|Page
The system should be directly installed into a ground fault circuit interrupter (GFCI). If the
use of an extension cord is required, the cord must be manufactured with a minimum of 16
gauge wire and care should be taken to avoid potenal tripping hazards.
We recommend that a licensed plumber or cered technician install the system.
This product is not to be used for general lighng / illuminaon.
Before You Begin
The following will be needed for installing the UV system:
Tools
Pipe cuer, hacksaw or other specialized tools required to cut into your exisng plumbing
(e.g. if you have PEX piping)
Soldering tools (torch, ux, emery cloth and solder)
Wrench (for ghtening ngs)
Other Materials
Inlet/outlet connecons
Teon™ tape
Water Quality Parameters
Treated water should be tested for at the least the parameters listed below. If the water exceeds
the listed parameters LUMINOR strongly recommends that appropriate pretreatment equipment
be installed (equipment required will depend on parameters being treated):
Hardness:
<7 gpg (120 mg/L) – if hardness level is 7 gpg or slightly below the
quartz sleeve must be cleaned periodically in order to ensure e-
cient UV penetraon; if above the water must be soened.
Iron (Fe):
<0.3 ppm (0.3 mg/L)
Manganese (Mn):
<0.05 ppm (0.05 mg/L)
Turbidity:
< 1 NTU
Tannins (organics):
<0.1 ppm (0.1 mg/L)
UVT (transmiance):
>85% (Please contact LUMINOR if water has a UVT that is less than
80% for pre-treatment recommendaons)
You can have your water tested at a private analycal laboratory or by your local dealer. It
is always recommended to install pre-ltraon of at least 5 microns prior to a LUMINOR UV
disinfecon
**
system.
**LUMINOR’s systems are tested for reducon of the MS-2 coliphage challenge microorgan-
ism to demonstrate a log reducon greater than or equal to the reducon caused by a dose
of 40mJ/cm
2
.