Instructions
22|Page
BLACKCOMB Standard Output System Specicaons
LUMINOR EQUIPMENT SPECIFICATIONS
Mul-Use /
Residenal systems (standard output lamps)
MODEL
LB4-02X
LB5-02X
LB6-02X
LB4-03X
LB5-03X
LB6-03X
LB4-06X
LB5-06X
LB6-06X
LB4-10X
LB5-10X
LB6-10X
LB4-15X
LB5-15X
LB6-15X
LB4-20X
LB5-20X
LB6-20X
NSF Class A Flow Rate
40mJ/cm
2
@ 70% UVT
(add “A” sux on LB6 models)
1.6 gpm 2.2 gpm 3.4 gpm 6.3 gpm 7.9 gpm N/A
6.1 lpm 8.3 lpm 13 lpm 24 lpm 30 lpm N/A
0.36 m
3
/hr 0.50 m
3
/hr 0.77 m
3
/hr 1.4 m
3
/hr 1.8 m
3
/hr N/A
NSF Class B Flow Rate
16mJ/cm
2
@ 70% UVT
(“B” sux on LB5,LB6 models)
2.9 gpm 5.2 gpm 7.6 gpm 13 gpm 22 gpm N/A
11 lpm 20 lpm 29 lpm 49 lpm 83 lpm N/A
0.66 m
3
/hr 1.2 m
3
/hr 1.7 m
3
/hr 3.0 m
3
/hr 5.0 m
3
/hr N/A
Flow Rate
16mJ/cm
2
@ 95% UVT
3.8 gpm 6.1 gpm 11 gpm 20 gpm 30 gpm 39 gpm
15 lpm 23 lpm 41 lpm 77 lpm 110 lpm 150 lpm
0.87 m
3
/hr 1.4 m
3
/hr 2.5 m
3
/hr 4.6 m
3
/hr 6.8 m
3
/hr 8.9 m
3
/hr
Flow Rate
30mJ/cm
2
@ 95% UVT
2.0 gpm 3 gpm 6 gpm 11 gpm 15 gpm 21 gpm
7.6 lpm 11.4 lpm 22.7 lpm 41 lpm 57 lpm 79 lpm
0.45 m
3
/hr 0.70 m
3
/hr 1.4 m
3
/hr 2.5 m
3
/hr 3.4 m
3
/hr 4.8 m
3
/hr
Flow Rate
40mJ/cm
2
@ 95% UVT
1.6 gpm 2.4 gpm 4.4 gpm 8.3 gpm 12 gpm 16 gpm
6.1 lpm 9.1 lpm 17 lpm 31 lpm 45 lpm 59 lpm
0.36 m
3
/hr 0.50 m
3
/hr 1.0 m
3
/hr 1.9 m
3
/hr 2.7 m
3
/hr 3.6 m
3
/hr
Port Size ½”FNPT ½”MNPT ¾”MNPT ¾”MNPT 1”MNPT 1”MNPT
Electrical 100-240V/50-60Hz. ±10%. 1A Max.
Plug Type American: NEMA 5-15P *See Note (below)
Lamp Power (Was) 8 15 22 39 50 42
Power (Was) 14 20 30 49 62 51
Replacement Lamp RL-210 RL-290 RL-470 RL-820 RL-999 RL-850
Replacement Sleeve RQ-210 RQ-290 RQ-470 RQ-820 RQ-999 RQ-850
Reactor
Dimensions
6.4 x 26.2 cm
(2.5 x 10.3”)
6.4 x 36.4 cm
(2.5 x 14.3”)
6.4 x 54.2 cm
(2.5 x 21.3”)
6.4 x 89.5 cm
(2.5 x 35.2”)
6.4 x 101.6 cm
(2.5 x 40.0”)
8.9 x 91.7 cm
(3.5 x 36.1”)
Chamber
Material
304 Stainless Steel, A249 Pressure Rated Tubing
Controller
Dimensions
17.2 x 9.2 x 10.2 cm (6.8 x 3.6 x 4”)
Operang
Pressure
0.7-10.3 bar (10-150 psi)
Operang Water
Temperature
2-40° C (36-104° F)
UV Monitor YES on all “LB6” models. Upgrade available for “LB5” models (NOT available on LB4 models)
Solenoid Output YES (oponal solenoid module (MOD-SOL1) sold separately)
Dry Contacts YES (remote alarm module (MOD-RAM) sold separately)
4-20mA Output YES (4-20mA module (MOD-420) sold separately)
Temperature Mgmt. Valve NA PN# 130031 PN# 130032 PN# 130033
Cooling Fan NO
OPTIONAL
(130014)
Lamp Change Reminder YES
Lamp Out Indicator YES
Shipping Weight
2.9 kg
(6.3 lbs)
3.6 kg
(7.9 lbs)
4.4 kg
(9.6 lbs)
6.0 kg
(13.2 lbs)
6.5 kg
(14.4 lbs)
8.2 kg
(18.0 lbs)
*Note: replace “X” with “1” for all 110V systems with North American NEMA 5-15
replace “X” with “2” for all 230V systems with European CEE 7/7
replace “X” with “3” for all 230V systems with Brish Standard, BS 1363
replace “X” with “4” for all 230V systems with Australian/NewZealand AS/NZ 3112