Instructions

20|Page
Temperature Management Devices
Your LUMINOR BLACKCOMB system is designed to run connuously to ensure opmal
disinfecon
**
. However, during periods when no water is drawn through the system, the energy
from the disinfecon
**
process can cause the temperature of the water inside the chamber to
rise. In extreme situaons elevated water temperature or the uctuaon in temperature can
lower the output of the UV lamp. In these cases, or if the elevated water temperature is a
nuisance, LUMINOR recommends one of the following forms of temperature management
devices.
Cooling Fan
Designed for use on the BLACKCOMB-HO systems, the “LUMI-cool
TM
” fan runs
connuously to cool the water by forced convecon. The long-life fan is powered
independently using a compact modular power adapter that operates from
100-240V/50-60Hz. ±10%. The cooling fan must only be supplied at SELV. Order
PN 130014.
Temperature Relief Valve (TRV)
On reaching a higher temperature, the TRV is designed to drain a small amount
of water to allow fresh, cooler water to enter the system. The TRV works without
power and comes complete with 10’ of drain line. Order PN 130031 for 1/2”
ports, PN 130032 for 3/4” ports, PN 130033 for 1” ports and PN 130034 for 1
1/2” ports.
Expansion Modules
BLACKCOMB
5.1
and BLACKCOMB
6.1
controllers incorporate an “Innite Expandability Port” (IEP)
which allows for expansion to the UV sensor and all other modules. Each module (including the
sensor) comes with both a male and female connecon. Connect any device to the controller
and all subsequent devices are then connected into the female end of last device added in a
daisy chain” conguraon. The UV sensor must only be supplied at SELV.
The following oponal expansion modules are available for use on BLACKCOMB
5.1
and BLACK-
COMB
6.1
UV
controllers. Contact your authorized distributor for purchasing informaon.
REMOTE ALARM CONNECTION MODULE: Allows
for a connecon to a remote device such as a buzzer,
light, alarm system, PLC, etc., via a pair of contacts.
In normal operaon the OK and COM contacts will
be connected, and in a fault condion (Low UV,
Lamp fail, Power Fail), the Fault and COM contacts
will be connected. Maximum contact rang is 30V
/ 1A (use 16-22 AWG). The remote alarm module
must only be supplied at SELV. Order PN MOD-RAM.