Instructions

19|Page
So Alarms: The following remaining errors give a 15 second audible chirp only
System Display Problem Resoluon
The module
indicated is no longer
communicang to with
the system.
Ensure all modules are
connected properly to the
system and to each other.
Modules can be tested
individually by plugging in
one at a me and cycling
power to the system.
Replace any module that is
not detected when plugged
directly into the controller.
Refer to ow meter manual for detailed
troubleshoong
Warning: Aer any hard alarm, the home or facility should be disinfected
**
. Follow the steps
under the “System Preparaon” heading.
Boil Water Advisory: If any failure occurs on a BLACKCOMB UV system, the
water must not be used for human consumpon unl the system is returned to
normal operaonal mode. If the water is used for human consumpon during
this period, the water must be boiled (minimum 20 minutes at a full boil) prior
to consumpon.