A nal module screen is displayed showing which specic modules were inialized.
The controller then displays the lamp opmizaon screen for 60 seconds to allow the lamp to
reach its opmum output. Finally, a nal “start-up complete” screen is displayed. The system will
now be ready to disinfect
**
water ow.
all detected modules lamp reaching max output successful start-up
BLACKCOMB
5.1
Operaonal Screens
On systems without the UV monitor, the default screen shows the LUMINOR Home Screen. At
any point during operaon the user is able to scroll through the LUMINOR Home Screen, Lamp
life remaining, QR Code, Contact Info and Maintenance Parts screens by pressing the buon
located on the front of the controller.
BLACKCOMB
6.1
Operaonal Screens
On systems with the UV monitor, the system will display the same screens as on the BLACK-
COMB
5.1
except the UV Intensity replaces the home screen. The UV Intensity screen displays
the level of UV light detected by the sensor. UV intensity can be aected by poor water quality,
scaling on the quartz sleeve and/or sensor, lamp failure or lamp expiring. The following screens
show the UV Intensity dropping.
Below 56%, the numbers and warning sign turn red and an audible chirp is given by the ballast
every 15 seconds. Below 51%, the screen is solid red and a constant audible alarm is given. This
alternates with a screen indicang “water may be unsafe for consumpon”. With the solenoid
module, the controller de-acvates the solenoid valve, shung o all water ow.