General Information
Product Nomenclature
LUXEON Z emitters are specied and binned under “hot” conditions comparable to those found in “real-world”
lighting products. The test conditions for LUXEON Z is 500mA DC with junction temperature at 85°C.
The part number designation is explained as follows:
L X Z n - a b c d - y
Where:
n 1 for LUXEON Z
a, b designates nominal ANSI CCT (27 for 2700K, 30 for 3000K, RB for Royal Blue)
c, d designates minimum CRI performance (7 for 70 CRI, 8 for 80 CRI, 9 for 90 CRI)
y 1 designates 1 SDCM
*
, 3 designates 3 SDCM and 5 designates 5 SDCM (only for 80 and 90 CRI versions.
70 CRI parts or lower will not have a SDCM designation and all parts are binned within a 5 step SDCM).
Therefore, 5 SDCM 3000K/80 CRI LUXEON Z will have the following part number:
L X Z 1 – 3 0 8 0 - 5
Average Lumen Maintenance Characteristics
LUXEON Z products are tested in compliance with LM-80. Please visit www.lumileds.com or contact your local
Lumileds Technical Solutions Manager for TM-21 extrapolations or other support.
Environmental Compliance
Lumileds is committed to providing environmentally friendly products to the solid-state lighting market.
LUXEON Z products are compliant to the European Union directives on the restriction of hazardous substances
in electronic equipment, namely the RoHS and REACH directives. Lumileds will not intentionally add the following
restricted material to the LUXEON Z: lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls
(PBB) or polybrominated diphenyl ethers (PBDE).
___________________________
* 1 SDCM is available on special request. Please contact your Sales representative.