Datasheet

DS103 LUXEON M Product Datasheet 20150205 ©2015 Lumileds Holding B.V. All rights reserved. 7
Optical and Electrical Characteristics
LUXEON M White at Test Current
[1]
, Junction Temperature = 85°C
Table 7.
Nominal
CCT
Part Number
Color Temperature
[2]
CCT
Typical (K)
Typ Total Included Angle
[2]
(°C) u0.90V
Typ Viewing Angle
[3]
(°C) 2u 1/2
2700K
LXR8-SW27, LXR8-RW27, LXR8-QW27
LXR9-SW27, LXR9-RW27, LXR9-QW27
2725
2725
140
140
120
120
3000K
LXR7-SW30, LXR7-RW30, LXR7-QW30
LXR8-SW30, LXR8-RW30, LXR8-QW30
LXR9-SW30, LXR9-RW30, LXR9-QW30
3045
3045
3045
140
140
140
120
120
120
3500K LXR8-SW35, LXR8-RW35, LXR8-QW35 3465 140 120
4000K
LXR7-SW40, LXR7-RW40, LXR7-QW40
LXR8-SW40, LXR8-RW40, LXR8-QW40
3985
3985
140
140
120
120
5000K
LXR7-SW50, LXR7-RW50, LXR7-QW50
LXR8-SW50, LXR8-RW50, LXR8-QW50
5028
5028
140
140
120
120
5700K
LXR7-SW57, LXR7-RW57, LXR7-QW57,
LXR9-SW57, LXR9-RW57, LXR9-QW57
5665
5665
140
140
120
120
6500K LXR7-SW65, LXR7-RW65, LXR7-QW65 6530 140 120
Notes for Table 7:
1. Test current is 700mA for LXRx-SWxx, 1400mA for LXRx-RWxx and 2800mA for LXRx-QWxx products.
2. Total included angle at which 90% of total luminous ux is captured.
3. Viewing angle is the o axis angle from lamp centerline where the luminous intensity is 1/2 of the peak value.
LUXEON M Royal Blue at Test Current
[1]
, Junction Temperature = 85°C
Table 8.
Color
Peak Wavelength, λ
p
[2]
Typical
Spectral
Half-width (nm)
[3]
Dλ
1/2
Typ. Temperature
Coecient
of Peak Wavelength
(nm/°C) Dλ
D
/ DT
J
Typ. Total
Included Angle
(°C)
[4]
u
90V
Typical
Viewing Angle
(°C)
[5]
2u
1/2
Minimum Typical Maximum
Royal Blue 445.0 nm 447.5nm 460.0nm 22 0.05 140 150
Notes for Table 8:
1. Test current is 700mA for LXR0-SR00, 1400mA for LXR0-RR00 and 2800mA for LXR0-QR00.
2. Royal Blue product is binned by radiometric power and peak wavelength rather than photometric lumens.
3. Spectral half-width is 1/2 of the peak intensity.
4. Total included angle at which 90% of total radiometric power is captured.
5. Viewing angle is the o axis angle from lamp centerline where the luminous intensity is 1/2 of the peak value.