Datasheet
DS103 LUXEON M Product Datasheet 20150205 ©2015 Lumileds Holding B.V. All rights reserved. 3
LUXEON M 6V products tested and binned at 1400mA follow the part numbering scheme:
L X R 7 - R W 3 0 - x x x x
L X R 7 - R W 4 0 - x x x x
L X R 7 - R W 5 0 - x x x x
L X R 7 - R W 5 7 - x x x x
L X R 7 - R W 6 5 - x x x x
L X R 8 - R W 2 7 - x x x x
L X R 8 - R W 3 0 - x x x x
L X R 8 - R W 3 5 - x x x x
L X R 8 - R W 4 0 - x x x x
L X R 8 - R W 5 0 - x x x x
L X R 9 - R W 2 7 - x x x x
L X R 9 - R W 3 0 - x x x x
L X R 0 - R R 0 0 - x x x x
L X R 9 - R W 5 7 - x x x x
LUXEON M 3V products tested and binned at 2800mA follow the part numbering scheme:
L X R 7 - Q W 3 0 - x x x x
L X R 7 - Q W 4 0 - x x x x
L X R 7 - Q W 5 0 - x x x x
L X R 7 - Q W 5 7 - x x x x
L X R 7 - Q W 6 5 - x x x x
L X R 8 - Q W 2 7 - x x x x
L X R 8 - Q W 3 0 - x x x x
L X R 8 - Q W 3 5 - x x x x
L X R 8 - Q W 4 0 - x x x x
L X R 8 - Q W 5 0 - x x x x
L X R 9 - Q W 2 7 - x x x x
L X R 9 - Q W 3 0 - x x x x
L X R 0 - Q R 0 0 - x x x x
L X R 9 - Q W 5 7 - x x x x
Average Lumen Maintenance Characteristics
Lumen maintenance for solid-state lighting devices (LEDs) is typically dened in terms of the percentage of initial
light output remaining after a specied period of time. Lumileds projects that LUXEON M products will deliver,
on average, 70% lumen maintenance (L70) at 50,000 hours of operation at a forward current of up to 700mA for
LXRx-Sxxx and 1400mA for LXRx-Rxxx and 2800mA for LXRx-Qxxxx. This projection is based on constant current
operation with junction temperature maintained at or below 135°C. This performance is based on Lumileds historical
data from tests run on similar material systems, and internal LM80 and reliability testing. Observation of design limits
included in this data sheet is required in order to achieve this projected lumen maintenance.
Environmental Compliance
Lumileds is committed to providing environmentally friendly products to the solid-state lighting market. LUXEON M
is compliant to the European Union directives on the restriction of hazardous substances in electronic equipment,
namely the RoHS directive. Lumileds will not intentionally add the following restricted materials to the LUXEON M
lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) or polybrominated diphenyl ethers
(PBDE).