DS064 LUXEON Rebel General Purpose Product Datasheet 20140205 ©2015 Lumileds Holding B.V. All rights reserved. 9
Mechanical Dimensions
Figure 1. Package outline drawing.
Notes for Figure 1:
- Do not handle the device by the lens—care must be taken to avoid damage to the lens or the interior of the device that can be damaged by
excessive force to the lens.
- Drawings not to scale.
- All dimensions are in millimeters.
- The Thermal Pad is electrically isolated from the Anode and Cathode contact pads.