Datasheet

DS064 LUXEON Rebel General Purpose Product Datasheet 20140205 ©2015 Lumileds Holding B.V. All rights reserved. 4
Luminous Flux Characteristics for LUXEON Rebel,
Thermal Pad Temperature=25°C
Table 1.
Performance at Test Current Typical Performance
at Indicated Current
Color Part Number Minimum Luminous Test Typical Luminous Drive
Flux (lm) Current Flux (lm) Current
F
V
[1]
(mA) F
V
[2]
(mA)
LXML-PWC1-0090 90 350 160 700
LXML-PWC1-0100 100 350 180 700
LXML-PWC1-0110 110 350 200 700
LXML-PWC1-0120 120 350 220 700
LXML-PWN1-0090 90 350 160 700
LXML-PWN1-0100 100 350 180 700
LXML-PWN1-0110 110 350 200 700
LXML-PWN1-0120 120 350 220 700
Notes for Table 1:
1. Minimum luminous flux performance guaranteed within published operating conditions. Lumileds maintains a tolerance of ± 6.5%
on flux measurements.
2. Typical luminous flux performance when device is operated within published operating conditions.
Flux Performance, Binning, and Supportability
LEDs are produced with semiconductor technology that is subject to process variation, yielding a range of flux performance that is approximately
Gaussian in nature. In order to provide customers with fine granularity within the overall flux distribution, Lumileds separates LEDs into fixed, easy
to design with, minimum luminous flux bins. To verify supportability of parts chosen for your application design, please consult your
Lumileds representative.
Luminous Flux Characteristics
Cool White
Neutral-White
Volume
Luminous Flux Bins