Datasheet

DS068 LUXEON Rebel & LUXEON Rebel ES Colors Product Datasheet 20150410 ©2015 Lumileds Holding B.V. All rights reserved. 4
Product Selection & Optical Characteristics
Product Selection Guide for LUXEON Rebel and LUXEON Rebel ES Colors at
Junction Temperature
[3]
Table 2.
Color Part Number
Performance @ 700mA
Minimum Luminous Flux (lm)
or Radiometric Power (mW)
Typical Luminous Flux (lm) or
Radiometric Power (mW)
Typical
Ecacy (lm/W)
or
Radiant Ecacy
Blue
LXML-PB02
50
60
70
80
58
67
75
83
28
32
36
40
Royal Blue
LXML-PR02-1100
LXML-PR02-1050
LXML-PR02-1000
LXML-PR02-0950
LXML-PR02-0900
LXML-PR02-0800
LXML-PR02-A900
[1]
1100 mW
1050 mW
1000 mW
950 mW
900 mW
800 mW
900 mW
1120 mW
1070 mW
1030 mW
970 mW
940 mW
890 mW
1030 mW
53%
51%
49%
46%
44%
42%
49%
Notes for Table 2:
1. LXML-PR02-A900 is a selection of color Bins 4,5 only.
2. Minimum luminous ux or radiometric power performance guaranteed within published operating conditions. Lumileds maintains a tolerance of ±6.5% on ux and power measurements.
3. LUXEON Rebel ES Lime is tested and binned at thermal pad temperature = 85°C, all other LUXEON Rebel Color emitters are tested and binned with thermal pad temperature = 25°C.
4. LUXEON Rebel ES Lime, ES Blue, Deep Red and PC Amber may also be sold under part numbers which denote a minimum ux level, similar to other parts in the portfolio, specied by
digits 9 through 12 of the part number.