Datasheet

DS106 LUXEON T Product Datasheet 20131101 ©2015 Lumileds Holding B.V. All rights reserved. 3
Product Selection Guide
Product Selection Guide for LUXEON T Emitters, Junction Temperature = 85°C
Table 1.
Typical Performance Characteristics at 350mA, 700mA, and 1000mA for LUXEON T, Junction Temperature = 85°C
Part Number
Nominal
ANSI CCT
CRI Luminous Flux (lm) Min Typical Luminous Flux (lm) Typical Forward Voltage (V
f
) Typical Efficacy (lm/W)
700mA 700mA 350mA 700mA 1000mA 350mA 700mA 1000mA 350mA 700mA 1000mA
LXH7-FW30 3000K 70 min 200 117 218 298 2.71 2.80 2.86 123 111 104
LXH7-FW40 4000K 70 min 210 133 249 340 2.71 2.80 2.86 140 127 119
LXH7-FW50 5000K 70 min 220 136 255 348 2.71 2.80 2.86 143 130 122
LXH7-FW57 5700K 70 min 220 136 255 348 2.71 2.80 2.86 143 130 122
LXH7-FW65 6500K 70 min 220 136 255 348 2.71 2.80 2.86 143 130 122
LXH8-FW27-Y 2700K 80 min 170 100 186 254 2.71 2.80 2.86 105 95 89
LXH8-FW30-Y 3000K 80 min 180 106 197 269 2.71 2.80 2.86 112 101 94
LXH8-FW35-Y 3500K 80 min 190 112 208 278 2.71 2.80 2.86 118 106 97
LXH8-FW40-Y 4000K 80 min 190 114 212 288 2.71 2.80 2.86 120 108 101
LXH8-FW50-Y 5000K 80 min 190 120 222 300 2.71 2.80 2.86 127 113 105
LXH9-FW30-Y 3000K 95 typ 130 86 160 216 2.71 2.80 2.86 91 82 76
Notes for Table 1:
1. Lumileds maintains a tolerance of ±6.5% on luminous flux and ±2 on CRI measurements.
Product Selection Guide for LUXEON T 3V Royal Blue, Junction Temperature = 85°C
Table 2.
Performance at Test Current
Color
Part
Number
Minimum
Radiometric Power (mW)
Typical
Radiometric Power (mW)
Typical Radiant
Efficacy (%)
Royal Blue LXH1 - FWRB 950 1040 53%
Note for Table 2:
1. Lumileds maintains a tolerance of ±6.5% on flux measurements.
2. Test current is 700mA for LXR0-SR00 products.