Datasheet
DS101 LUXEON R Product Datasheet 20140709 ©2015 Lumileds Holding B.V. All rights reserved. 16
Luminous Flux Bins
Table 7 lists the standard photometric luminous ux bins for LUXEON R emitters (tested and binned at 700mA D.C.,
Junction Temperature = 85°C. Minimum luminous ux performance within published operating conditions. Lumileds
maintains a tolerance of ±6.5% on luminous ux measurements.
Although several bins are outlined, product availability in a particular bin varies by production run and by product
performance. Not all bins are available in all CCT’s.
Table 7. Flux Bins
Bin Code
Minimum Photometric Flux
(lm)
Maximum Photometric Flux
(lm)
G 160 170
H 170 180
J 180 190
K 190 200
L 200 210
M 210 220
N 220 230
P 230 240
Q 240 250
R 250 260
S 260 270
T 270 280
U 280 290
V 290 300
W 300 310
Notes for Table 7:
1. Minimum luminous ux performance within published operating conditions. Lumileds maintains a tolerance of ±6.5% on luminous ux measurements.