Datasheet

DS107 LUXEON Rebel PLUS Product Datasheet 20140930 ©2015 Lumileds Holding B.V. All rights reserved. 4
Electrical Characteristics
Electrical Characteristics at 350mA for LUXEON Rebel PLUS,
Junction Temperature = 85°C
Table 3.
Nominal
ANSI CCT
Forward Voltage V
f
[1]
(V)
Typical Temperature Coecient
of Forward Voltage
[2]
(mV/°C)
DV
F
/ DT
J
Typical Thermal Resistance
Junction to Thermal Pad
(°C/W)
Ru
J-C
Min Max
2700K 2.5 3.00 -1.0 to -3.0 9
3000K 2.5 3.00 -1.0 to -3.0 9
3500K 2.5 3.00 -1.0 to -3.0 9
4000K 2.5 3.00 -1.0 to -3.0 9
5000K 2.5 3.00 -1.0 to -3.0 9
Notes for Table 3:
1. Lumileds maintains a tolerance of ±0.06V on forward voltage measurements.
2. Measured between T
J
= 25°C and T
J
= 110°C at I
f
= 350mA.
Absolute Maximum Ratings
Table 4.
Parameter Maximum Performance
DC Forward Current (mA)
[2]
1000
Peak Pulsed Forward Current
[3]
1000
ESD Sensitivity < 8000V Human Body Model (HBM) Class 3A JESD22-A114-E
LED Junction Temperature
[1]
150°C
Operating Case Temperature at 700mA -40°C - 135°C
Storage Temperature -40°C - 135°C
Soldering Temperature JEDEC 020c 260°C
Allowable Reow Cycles 3
Reverse Voltage (V
r
)
LUXEON Rebel PLUS LEDs are not designed to be driven in reverse
bias
Notes for Table 4:
1. Proper current derating must be observed to maintain junction temperature below the maximum. For additional information on thermal measurement guidelines please refer to Application
Brief AB33.
2. Residual periodic variations due to power conversion from alternating current (AC) to direct current (DC), also called “ripple’, with frequencies 100 Hz and amplitude 300mA are acceptable,
assuming the average current throughout each cycle does not exceed 1000mA.
3. Pulsed operation with a peak drive current of 1000mA is acceptable if the pulse on-time is 5 ms per cycle and the duty cycle is 50%.
JEDEC Moisture Sensitivity
Table 5.
Level Floor Life
Soak Requirements
Standard
Time Conditions Time Conditions
1 Unlimited
[ 30°C / 85% RH
168 Hrs. + 5 / -0 Hrs. 85°C / 85% RH