Datasheet
DS107 LUXEON Rebel PLUS Product Datasheet 20140930 ©2015 Lumileds Holding B.V. All rights reserved. 14
Luminous Flux and Forward Voltage Bins
Table 7 lists the standard photometric luminous ux bins for LUXEON Rebel PLUS emitters (tested and binned
at 350mA D.C., Junction Temperature = 85°C. Minimum luminous ux performance within published operating
conditions. Lumileds maintains a tolerance of ±6.5% on luminous ux measurements.
Although several bins are outlined, product availability in a particular bin varies by production run and by product
performance.
Not all bins are available in all CCT’s.
Table 7. Luminous Flux Bins
Bin Code
Minimum Photometric Flux
(lm)
Maximum Photometric Flux
(lm)
A
[2]
75 85
B 85 95
C 95 105
D 105 115
E 115 125
F 125 135
Notes for Table 7:
1. Minimum luminous ux performance within published operating conditions. Lumileds maintains a tolerance of ±6.5% on luminous ux measurements.
2. For LX18-P127 minimum ux is 80 lm.
- A is the cat code for 80-85 lm for the above emitters.
3. For LX18-P135 and LX18-P140 minimum ux is 90 lm.
- B is the cat code for 90-95 lm for the above emitters.
Table 8 lists minimum and maximum V
f
bin values per emitter (tested and binned at 350mA). Although several bins
are outlined, product availability in a particular bin varies by production run and by product performance.
Table 8. V
f
Bins
Bin Code
Minimum Forward Voltage
(V)
Maximum Forward Voltage
(V)
1 2.50 2.75
2 2.75 3.00