DS115 LUXEON CoB Core Range Product Datasheet 20150219 ©2015 Lumileds Holding B.V. All rights reserved. 6
Table 1g. Product Selection Guide for LUXEON CoB 1211
Product
CRI
[1]
Nominal
CCT
Luminous Flux
[1, 2]
Ecacy
(lm/W)
Test Current
(mA)
LES
[3]
(mm)
Part Number
Min. Typ. Min. (lm) Typ. (lm)
LUXEON
CoB 1211
70 73 3000K 4775 5200 122 1200 19.0 LHC1-3070-1211
70 73 3500K 4775 5200 122 1200 19.0 LHC1-3570-1211
70 73 4000K 5050 5600 130 1200 19.0 LHC1-4070-1211
70 73 5000K 5050 5600 130 1200 19.0 LHC1-5070-1211
70 73 5700K 5050 5600 130 1200 19.0 LHC1-5770-1211
80 82 2200K 3550 3975 92 1200 19.0 LHC1-2280-1211
80 82 2700K 4150 4600 106 1200 19.0 LHC1-2780-1211
80 82 3000K 4500 5000 115 1200 19.0 LHC1-3080-1211
80 82 3500K 4675 5200 119 1200 19.0 LHC1-3580-1211
80 82 4000K 4775 5200 122 1200 19.0 LHC1-4080-1211
80 82 5000K 4850 5300 124 1200 19.0 LHC1-5080-1211
90 97 2200K 2925 3425 80 1200 19.0 LHC1-2290-1211
90 97 2700K 3500 3875 90 1200 19.0 LHC1-2790-1211
90 97 3000K 3650 4000 93 1200 19.0 LHC1-3090-1211
90 97 3500K 3775 4200 96 1200 19.0 LHC1-3590-1211
90 97 4000K 4050 4400 100 1200 19.0 LHC1-4090-1211
Notes for Table 1:
1. Lumileds maintains a tolerance of ±6.5% on luminous ux, ±2 on CRI.
2. Maximum luminous ux is 10% above typical luminous ux.
3. Light Emitting Surface (LES) is the inner diameter (phosphor area) inside the dam.
Table 2. Optical Characteristics
Nominal
CCT
Typical Total Included Angle
[1]
(degrees)
u
0.90V
Typical Viewing Angle
[2]
2u
1/2
L2C1 – xxxx120206xxx 135 115
LHC1 - xxxx - xxxx 135 115
Notes for Table 2:
1. Total angle at which 90% of total luminous ux is captured.
2. Viewing angle is the o axis angle from lamp centerline where the luminous intensity is ½ of the peak value.