Datasheet

DS118 LUXEON Q Product Datasheet 20141120 ©2015 Lumileds Holding B.V. All rights reserved. 4
Electrical Characteristics
Electrical Characteristics at test current for LUXEON Q
Junction Temperature = 85°C
Table 3.
Nominal
ANSI CCT
Forward Voltage V
f
(V)
[1]
Typical Temperature
Coecient
of Forward Voltage
[2]
(mV/°C)
DV
F
/ DT
J
Typical Thermal Resistance
Junction to Thermal Pad
(°C/W)
Rθ
J-C
Minimum Maximum
2700K 2.50 3.25 -1.6 7
3000K 2.50 3.25 -1.6 7
3500K 2.50 3.25 -1.6 7
4000K 2.50 3.25 -1.6 7
5000K 2.50 3.25 -1.6 7
5700K 2.50 3.25 -1.6 7
Notes for Table 3:
1. Lumileds maintains a tolerance of ± 0.06V on forward voltage measurements.
2. Measured between T
J
= 25°C and T
J
= 110°C at I
f
= 350mA.
Absolute Maximum Ratings
Table 4.
Parameter LUXEON Q
DC Forward Current (mA)
[1] [2]
1050
Peak Pulsed Forward Current (mA)
[1] [3]
1200
ESD Sensitivity < 8000V Human Body Model (HBM) Class 3A JESD22-A114-E
LED Junction Temperature
[1]
135°C
Operating Case Temperature at 700mA -40°C - 135°C
Storage Temperature -40°C - 135°C
Soldering Temperature JEDEC 020c 260°C
Allowable Reow Cycles 3
Reverse Voltage (Vr)
[4] [5]
LUXEON Q LEDs are not designed to be driven in reverse bias
Notes for Table 4:
1. Proper current derating must be observed to maintain junction temperature below the maximum. For additional information on thermal measurement guidelines please refer to Application
Brief AB118 (not available yet).
2. Residual periodic variations due to power conversion from alternating current (AC) to direct current (DC), also called “ripple”, with frequencies
100 Hz and amplitude 150mA are acceptable, assuming the average current throughout each cycle does not exceed 1050mA.
3. Pulsed operation with a peak drive current of 1200mA is acceptable if the pulse on-time is 5 ms per cycle and the duty cycle is 50%.
4. Transient reverse voltages and surge currents due to electrical switching or supply interruptions are acceptable if these events do not last for more than 10ms, the amplitude of the reverse
voltage does not exceed 5V and the reverse current is less than 200μA.
5. Max 5V reverse for up to 10s is an acceptable beginning of life, one time test condition.