Installation & Assembly

MOUNTING INSTRUCTIONS
SUITABLE FOR WATTAGES:
ON-OFF WIRING METHOD:
Universal voltage driver permits operation at 120V through 277V, 50 or
60 Hz. Units ordered with (480V) sufx are 480V, 60Hz. For Non-Dimming,
follow the wiring directions as in FIG. 1
1. Connect the GROUND wire from xture to supply ground
2. Connect the white xture lead to the (-) COMMON supply lead
3. Connect the black xture lead to the (+) LINE supply lead
0-10V DIMMABLE WIRING METHOD:
Universal voltage driver permits operation at 120V through 277V, 50 or 60
Hz. For 0-10V Dimming, follow the wiring directions as in gure 2
1. Connect the GROUND wire from xture to supply ground
2. Connect the white xture lead to the (-) COMMON supply lead
3. Connect the black xture lead to the (+) LINE supply lead
4. Connect the purple xture lead to the (V+) DIM lead
5. Connect the gray xture lead to the (V-) DIM lead
5. Cap the yellow xture lead, if present. DO NOT connect
FIGURE 1
FIGURE 2
TROUBLESHOOTING:
1. Check that the line voltage at xture is correct
2. Is there voltage at the lamp xture wires? If there is no voltage, check
all connections
3. Ensure that the xture is grounded properly
VER01.16
LIGHTING
FIXTURE
(+) LINE
(-) COMMON
GROUND
BLACK
WHITE
GROUND
LIGHTING
FIXTURE
(+) LINE
(-) COMMON
(+)DIM V+
BLACK
WHITE
PURPLE
GROUND
GRAY
YELLOW
GROUND
(-)DIM V-