Datasheet

Lumberg Connect
GmbH
Im Gewerbepark 2
58579 Schalksmühle
Processing instruction
M16 circular connectors
03V02EN
Page 10 of 11
3 Quality assurance
For all working and processing steps and alterations (e.g. product launch, changes of the
cable, changes of the tool or machine…), which may affect the product quality, the
responsible departments have to take care for appropriate quality assurance steps.
3.1 Quality features
The following quality features must be taken into consideration:
Cable stripping
Wire Stripping
Wire soldering
Tightening torques
3.1.1 Cable stripping
The user must ensure that the insulation of the wires is not damaged during the stripping
process. The stripping lengths specified in section 2 must be maintained.
A tolerance of ± 3 mm is permitted.
3.1.2 Wire stripping
The user must ensure that the individual wire strands are not damaged during the stripping
process. The stripping lengths specified in section 2 must be maintained.
A tolerance of ± 0,5 mm is permitted.
3.1.3 Wire soldering
It is important to ensure that the individual wire strands do not stick out and cause a short
circuit. Furthermore it is not allowed to reduce spacings between electrical conducting
elements, e.g. by protruding tin solder.
3.1.4 Tightening torques
Tightening torque M16: 1 3 Nm
Screws for strain relief M2: 15 cNm
Screw for housing M2,5: 30 cNm