Data Sheet
Rated Voltage: 125 V
Rated Impulse Voltage: 1.5 kV
Operating Voltage: 120 V AC/DC
Rated Current: 16 x 8 A (pin-Ø 1 mm), 3 x 10 A (contact-Ø 1.5 mm)
Insulation Resistance: ˃ 10^9 Ohm
Mating Cycles: ≤ 100
Ambient Temperature (Operation): -25°C to +80°C
Protection Degree / IP Rating: IP67
Pollution Degree: 3 acc. to DIN EN 60664-1 (VDE 0110-1)
Clearance / Creepage Distance: acc. to DIN EN 60664-1 (VDE 0110-1)
Overvoltage Category: II acc. to DIN EN 60664-1 (VDE 0110-1)
Materials
Contact Base Material: CuZn
Contact Plating: Cu/Au
Contact Bearer Material: PBT
Contact Bearer Color: white
Flammability Class (Contact Bearer): UL 94 V0
Molded Body Material: TPU
Molded Body Color: black
Flammability Class (Molded Body): UL 94-HB
Attachment Material: CuZn, nickel-plated
O-Ring Material: FKM
Cable Data
Cable Number: 242
Conductor Size: 16x0.5mm² + 3x1.0 mm²
Number of Wires: 19
Minimal Bending Radius (Fixed Inst): ˃ 5 x D
Minimal Bending Radius (Flexible Inst): ˃ 10 x D
Cycles (Bending): ˃ 2 M
Conductor material: Cu
Cable Jacket Material: PUR
Cable Jacket Color: black
Cable Diameter D: Ø 11.60 ±0.30 mm
Wire Insulation Material: PP
Insulated Wire Diameter: 16x Ø1.45 mm + 3x Ø1.95 mm
Ambient Temperature (Fixed Installation): -50°C to +80°C
Ambient Temperature (Flex Installation): -25°C to +80°C
Ambient Temperature (Drag Chain Inst): max. +60°C
UL Cable Type: AWM: 21198 / 20549
Flammability Class (Cable Jacket): IEC 60332-2, VDE 0482-265-2-2, EN 50265-2-2, FT2; flame-retardant
Safety & Environmental Compliance
RoHS Compliant: yes
Resistances
Halogenfree: IEC 60754-1, VDE 0482-267, EN 50267-2-1
Notes
Protection Degree / IP Rating Note: * only if mounted and locked in combination with Hirschmann / Lumberg connector.
Note Derating: * Notice derating
Note: Do not connect / disconnect under load.
Particularities: When the connector is unlocked and in risk of pollution the connector has to be covered with a protective cap ≥ IP54.
Variants
Item # Item Description Cable Length
104327 RSUF 19-242/2 M 2 m