2.2 Output Zone/Channel Connections Table—For Trinity Multi -zone TRINITY POWER CORD SERIES Either 9, or 12 output channel options are available for driving and dimming LEDs. Channels are assigned to zones as shown in the following tables. A 9 channel option will provide 9 zones for dimming and a 12 channel option will provide 12 zones for dimming. 9/12 Channel - Zone Connection Table 12.
CONTENTS MECHANICAL DIMENSIONS & SPECIFICATIONS ...................................... 3 SPECIFICATIONS………………………………………………………4 2.0 SCOPE ............................................................................................................................... 8 3.0 OWNER RESPONSIBILITIES .................................................................................. 8 4.0 EMC COMPLIANCE ..................................................................................................... 8 5.
(1)TRINITY PC ANALOG, (1) COMMERCIAL DIMMING PANEL WITH (2) 0-10VDC ANALOG CONTROL SIGNALS 1.0 MECHANICAL DIMENSIONS AC INPUT DC OUTPUT DIMENSIONS: INCHES [MM] CORD LENGTH: 65 [1,651] Note: This wiring configuration provides dimming control for zones 1 and 2 simultaneously and separate dimming control for zones 3 and 4 simultaneously with a commercial dimming interface comprising (2) 0-10Vdc control signals.
1.1 SPECIFICATIONS Table 1 Input Specifications Rated Input Voltage And Frequency 115 to 125 Vac 47-63 Hz Rated Input Current 2.4-2.2 A Power Factor EN61000-3-2 @ 115 Vac, 100% load 0.
11.
11.
Table 9 11.3 Analog Interface Specifications Analog Interface Specifications The TRINITY PC ANALOG is compatible with commercial dimming panels and wall box dimmer products meeting IEC 60929 requirements. Control Method Analog 0-10Vdc IEC 60929 or ESTA E1.
2.0 SCOPE 11.2 The TRINITY PC is intended for powering and dimming Class 2 low voltage lighting systems. It is intended for installation in non-plenum locations in accordance with required local, state, provincial, country and NEC/CEC regulations. This manual provides general installation, use and application guidelines for the TRINITY PC. It should be read in conjunction with product datasheets. Data sheets may be downloaded at www.powervector.com.
11.0 0-10 Vdc ANALOG INTERFACE 11.1 LED Status Indicator INSTALLATION GUIDELINES AND SAFETY REQUIREMENTS Analog Dimming Active This power unit has been evaluated to the requirements for: UL8750 1st Edition: LED Light Equipment for Use in Lighting Products Power Indicator Zone #4 Output Channels 10,11,12 5.0 5.1 ELECTRICAL REQUIREMENTS This power unit is intended for connection to a 20A branch circuit and an appropriate disconnect device shall be provided as part of the building installation.
6.0 10.8 MULTI CHANNEL CONTROL MODES MOUNTING ORIENTATION The Trinity PC is able to link certain output channels together so that For sufficient cooling, the TRINITY PC must be mounted in either a vertical or horizontal orientation as shown: Vertical orientation provides the best cooling option they will respond on the same DMX channel.
10.7 STANDALONE TEST MODES 7.0 7.1 Test modes are specified by address location and may be used to Input specifications are defined in table 1 on page 4 of this debug network connections or provide standalone color changing options without the need for a DMX controller. Colours are assuming LED loads are connected in RGB configuration as shown on page 15, section 9.
8.3 Output Voltage Dynamic Range The Trinity PC has a dynamic voltage range options of 6 Vdc to 27 Vdc or 12 Vdc to 47 Vdc depending on configuration as referenced in table 6 at the beginning of this manual. This allows the Trinity PC to accommodate a range in both number of LEDs utilized in a string as well as a variation in forward voltage drops.
9.0 DIMMING CONTROL OPTIONS 10.4 DMX Cabling The DMX cable should meet EIA485 requirements. The characteristics for this cable include low capacitance, twisted pair, shielded, and designed for high speed data. Twisted pair Ethernet cabling referred to as Category 5 cable may be a cabling option upon successful evaluation in the end use application.
10.3 DMX Interface Connections 10.2 DMX LED Status Indicator The table below references required wiring connections for RJ45 like (IEC 60603-7 8 Position) Modular Connectors.