Owner's manual

THEA 56 Specifications
Input
Output
System Protection
Safety and EMI/EMC
Environmental
Control Interface
Rated Input Voltage 120 to 277 Vac
Rated Input Frequency 50/60 Hz
Power Factor EN61000-3-2 @120 Vac or 277 Vac 0.95 W/VA; 100% load
Input Current Total Harmonic Distortion @120 or 277 Vac 17% max, 100% load
Rated Output Power 58.8 W max
Efciency @240 Vac (no load on auxiliary output) 88% full load
System Power Cycle Delay 0.6 second typical
Output Current Tolerance +/-5 % of nominal
Auxiliary Voltage 5 Vdc @ 400 mA, 12 Vdc @ 164 mA; less than 1% load/line regulation
Output Over voltage, over current, short circuit protection
Over Temperature Power supply will throttle back output current gradually when case
temperature reaches 80°C/176°F nominal.
Agency Approvals UL 8750 Class 2 outputs, LVD EN61347-2-13, EN61347-1
Emissions FCC Title 47, Part 15, EN55015; EN55022, Class B
Immunity EN61547, EN55024
EMC EN61000-3-2 (Class C); EN61000-3-3
Location Rating IP50 Dry/Damp Location
Operating Ambient Temperature -20°C to 55°C / -4°F to 131°F
Maximum Case Temperature T
c
=75°C / 167°F
Storage Ambient Temperature -40°C to 80°C/ -40°F to 176°F
Relative Humidity 5% to 95% noncondensing
Mean Time Between Failure
(MIL HDBK-217F)
>200,000 hours @ 65°C / 149°F
Control Method Analog 0-10 Vdc, IEC 60929 Outputs 0.5 mA max or variable 0-10 Vdc
Voltage Source; Class 2 outputs.
Loss of Analog Input Signal Outputs will go to 100% light intensity in less than 1 second
LSPS05 / THEA 56
© 2014 LumaStream www.lumastream.com +1 (727) 827-2805