Owner's manual
BoilerSpection HD/SD Manual Appendix 85
8 Appendix
Specifications
Infrared Imaging Camera and Lens
Resolution 320 x 240 pixels
Wavelength 3.9 µm
Detector Type Uncooled focal plane array
Measurement
Range
HD: 400°C to 1600°C (752°F to 2,912°F)
SD: 500°C to 1600°C (932°F to 2,912°F)
Lens Diameter HD: Outer diameter of lens system is 3.39” (86 mm)
SD: Outer diameter of lens system is 1.65” (42 mm)
Optical Field of
View
46° horizontal by 36° vertical
Protective Hardware
Camera Housing HD: IP54 with vortex air cooling
SD: IP66 with vortex air cooling
Borescope Lens
Housing
HD: 304SS - Stainless steel shroud with integral air cooling and purge
SD: 310SS - Stainless steel shroud with integral air cooling and purge
Auto Retract Device
Fully automated system retracts camera in the event of power failure or loss of air
supply
Field Switch
Enclosure
IP67 / NEMA 4X (see drawings in Chapter 7)
Communications
Camera IP addressable over Ethernet
Software and Computer
Computer Requirements vary based on monitoring needs. Exact computer specifications will be
provided with your sales documentation.
Software See separate software manual for details and see section 2.3.7 in this manual for an
overview.