Owner manual
Chapter 11
______________________________________________________________________
_____________________________________________________________________________
BE6028-14 3434i SF6 Leak Detector LumaSense Technologies A/S
Page 127 of 191
The only regular maintenance required for the 3434i is:
Calibration – approximately every 3 months (see Chapter 12).
Changing the fine air-filter paper in the internal and external air-
filtration units (see section 11.1).
Cleaning of the filter in the ventilation unit (see section 11.2).
11.1 Changing the Fine Air-filters
The monitor is equipped with an internal filtration unit.
The internal unit is mounted on the air-inlet, on the back panel. This
is shown in Fig.11.1.
Fig.11.1 The internal air-filtration unit mounted on the back panel of
the monitor.
The internal air-filtration unit can be removed simply by unscrewing
the unit by hand. The unit is shown in Fig.11.2.
Fig.11.2 The internal air-filtration unit
Inside the unit, a fine (10µm) filter-paper removes fine dust particles
and other suspended matter from air samples before they reach the
measurement chamber of the Monitor.