Product Specications
Construction
• Die-cast aluminum housing with hinged, die-cast
aluminum door
• Sliptter mounts 2-3/8” vertical or horizontal
tenons. Downward facing only.
• IP65 rated housing enclosure
• 10-position lumen select switch accessible via
hinged housing door
Optics
• UV-resistant polycarbonate optics
• Full cutoff when mounted at 0 degrees tilt
• 4000K CCT, 70CRI minimum standard
• IP66 optical enclosures
Electrical
• -40°C minimum operating temperature
• 40°C maximum operating temperature
• >0.9 power factor
• <20% total harmonic distortion
• Class P drivers incorporate internal MOVs
designed to withstand 6kV of surge
• 0-10V dimming driver is standard
• 3-PIN NEMA twistlock photocontrol receptacle
and photocontrol included
Finish
• Standard color is bronze
• Finish only warrantied for a period of 1 year
Shipping Data
• LAS45: 14.0 lbs. (6.4 kgs.)
• LAS100: 18.0 lbs. (8.2 kgs.)
Model Number
1
Distribution Voltage
LAS45S=450W HID Equivalent, 10-Position Lumen Selectable
LAS100S=1,000W HID Equivalent, 10-Position Lumen Selectable
T3=Type III
T4=Type IV
T5=Type V
[Blank]=Universal, 120-277V
HV=High Voltage, 347-480V
2, 3
NOTES:
1. DesignLights Consortium® Qualied. Refer to www.designlights.org Qualied Products List under Family Models for details.
2. Supplied with shorting cap. Use NEMA 3-PIN twistlock photocontrol that matches the input voltage used (either 347V or 480V) as desired.
3. High Voltage (HV) only available with LAS45 housing.
Stock Ordering Information
SAMPLE NUMBER: LAS45S-T4
Model Number
1,2
Distribution Voltage Options Accessories (Order Separately)
LAS45=450W HID Equivalent
LAS100=1,000W HID Equivalent
T3=Type III
T4=Type IV
T5=Type V
[Blank]=Universal, 120-277V
HV=High Voltage, 347-480V
3
MS/DIM-L40W=Motion Sensor for
Dimming Operation, 21’ - 40’ Mounting
Height
FSIR-100=Wireless Conguration Tool for
Motion Sensor
4
RABBZ=Wall Mount Tenon Adapter
RABX-BZ=Pole Mount Tenon Adapter
NOTES:
1. DesignLights Consortium® Qualied. Refer to www.designlights.org Qualied Products List under Family Models for details.
2. Standard lead times apply. Sensor versions do not include lumen select switch. Max light output can be eld-programmed via the motion sensor with the accessory conguration tool.
3. High Voltage (HV) only available with LAS45 housing.
4. This tool enables adjustment to Motion Sensor (MS) parameters including high and low modes, sensitivity, time delay, cutoff and more. Consult your lighting representative for more information.
Ordering Information
SAMPLE NUMBER: LAS45-T4-MS/DIM-L40W
Ambient
Temperature
TM-21 Lumen Maintenance
(54,000 Hours)
Theoretical L70
(Hours)
Up to 40°C 85.80% 126,000
Energy and Performance Data
Lumen Maintenance
POWER Mounting Tilt
1 2 @ 90° 2 @ 120° 2 @ 180° 3 @ 90° 3 @ 120° 4 @ 90°
LAS45 Sliptter 0° 0.48776 0.77155 1.10981 0.9737 1.25749 1.32041 1.26178
LAS45 Sliptter 10° 0.48815 0.85358 1.21680 0.97500 1.30520 1.53192 1.30650
LAS45 Sliptter 20° 0.48802 1.15778 1.44040 0.97656 1.64372 2.10210 1.64619
LAS45 Sliptter 30° 0.48776 1.41297 1.66088 0.97188 1.89241 2.58219 1.89605
LAS45 Sliptter 45° 0.48672 1.73303 1.97171 0.97448 2.21949 3.20801 2.22430
LAS100 Sliptter 0° 0.60398 0.88777 1.23721 1.20770 1.48902 1.52074 1.49162
LAS100 Sliptter 10° 0.60385 1.17130 1.54141 1.20380 1.76462 2.10002 1.76514
LAS100 Sliptter 20° 0.60359 1.59679 1.91997 1.20224 2.19141 2.90810 2.19466
LAS100 Sliptter 30° 0.60320 1.99550 2.28956 1.20354 2.59064 3.67016 2.59545
LAS100 Sliptter 45° 0.60346 2.47832 2.77628 1.20094 3.06969 4.65127 4.37489
Mounting Details
Mounting Congurations and EPAs