SDS
Huizhou Highpower Technology Co., Ltd.
Safety Data Sheet
Date of Issue: Mar-25-2015 File No.: HP-SDS-032501
Page 6 of 6
This sheet is provided as technical information only. The information and recommendations set forth are made in good faith and
believed to be accurate as of the date of preparation. Huizhou Highpower Technology Co., Ltd. make no warranty, expressed or implied,
with respect to this information and disclaims all liabilities from reliance on it.
Incompatible products
Strong acids. Strong oxidizing agent. Strong bases.
8. Exposure Controls/Personal Protection
8.1 Exposure Guidelines
Chemical Name
ACGIH TLV
OSHA PEL
NIOSH IDLH
Nickel-hydroxide
12054-48-7
TWA: 0.2 mg/m
3
Ni
inhalable fraction
TWA: 1 mg/m
3
(vacated)
(as Ni
TWA: 1 mg/m
3
(as Ni)
IDLH: 10 mg/m
3
(as
Ni)
TWA: 0.015 mg/m
3
(except Nickel
carbonyl Ni)
Nickel
7440-02-0
TWA: 1.5 mg/m
3
TWA: 1 mg/m
3
(vacated) TWA: 1 mg/m
3
IDLH: 10 mg/m
3
TWA: 0.015 mg/m
3
Manganese
7439-96-5
TWA: 0.02 mg/m
3
respirable fraction
TWA: 0.1 mg/m
3
inhalable fraction TWA:
0.02mg/m
3
Mn
TWA: 0.1 mg/m
3
Mn
(vacated) TWA: 1 mg/m
3
fume
(vacated) STEL: 3 mg/m
3
fume
(vacated) Ceiling:
5
mg/m3
Ceiling: 5 mg/m
3
fume
Ceiling: 5mg/m
3
Mn
IDLH:500 mg/m
3
( (as
Mn)
TWA: 1mg/m
3
ST: 3 mg/m
3
Cobalt
7440-48-4
TWA: 0.02mg/m
3
TWA: 0.1 mg/m
3
dust and
fume
(vacated) TWA: 0.05
mg/m
3
dust and fume
IDLH:20 mg/m
3
( (as
Co) dust and fume
TWA: 0.05mg/m
3
dust
and fume
Potassium-hydroxide
1310-58-3
TWA:C 2 mg/m
3
(vacated) Ceiling: 2 mg/m
3
TWA:C 2 mg/m
3
Aluminum
7429-90-5
TWA:1mg/m
3
TWA:15mg/m
3
total dust
TWA: 5mg/m
3
respirable
fraction (vacated)
TWA:10mg/m
3
Total
dust
TWA:5mg/m
3
Respirable dust
Sodium-hydroxide
1310-73-2
TWA:C 2 mg/m
3
OSHA: 10 mg/m
3
TWA:C 2 mg/m
3
IDLH: 10 mg/m
3
TWA: 2 mg/m
3
Cobalt hydroxide
21041-93-0
TWA 0.1 mg/m
3
-
ACGIH TLV: American Conference of Governmental Industrial Hygienists-Threshold Limit Value
OSHA PEL:Occupational Safety and Health Administration-Permissible Exposure Limits
NIOSH IDLH Immediately Dangerous to Life or Health
Other Exposure Guidelines:
Vacated limits revoked by the court of Appeals decision in AFL-CLO v. OSHA, 965F, 2d
962(11th Cir., 1992) See section 15 for national exposure control parameters.
8.2 Appropriate engineering controls
Engineering Measures:
Showers、 Eyewash stations、Ventilation systems