Service Manual User guide
General Information, Specifications and Maintenance
2.16
Model 644E-42/944E-42 Rev. 6/04
Fuses - Standard Blade Style: 644E-42 944E-42
F25 - Lights Main (Option) 40 amps 40 amps
F26 - Condenser Fan (Option) 25 amps 25 amps
F27 - Open — —
F28 - Open — —
Relays:
E1 - Transmission Control 12 volt 12 volt
E2 - Ignition 12 volt 12 volt
E3 - Neutral Start 12 volt 12 volt
E4 - Back-Up Alarm 12 volt 12 volt
E5 - Stability Brake
(644E-42 SN 0160003877 944E-42 SN
0160003881 & Before)
E5 - Open
(644E-42 SN 0160003878 944E-42 SN
0160003882 & After)
12 volt
—
12 volt
—
E6 - Stability Lock 12 volt 12 volt
E7 - Boom Proximity 12 volt 12 volt
E8 - Light Power (Option) 12 volt 12 volt
E9 - Closed Cab Power (Option) 12 volt 12 volt
E10 - Open — —
Engine Fuel Pump (Inside Engine Compartment)
(944E Only)
N/A 12 volt
Cold Start Grid Heater Fuses:
Mega Bolt-On, 125 amp 2 (Optional) 2 (Standard)
ECM Fuses, Standard Blade - Mini Style:
ECM Diagnostic System N/A (3) @ 7.5 amp, (3) @ 10 amp