Pipe Thread Fittings To install National Pipe Thread (NPT) fittings:
1. Apply sealant sparingly to male pipe threads only, avoiding the first few
threads at the end of the fitting.
Note:
Do not use Teflon tape or excessive amounts of sealant. System
contamination will result.
2. Install fitting and tighten per Table 3-8.
Table 3-8: Pipe Thread Fittings (Steel)
Jump Starting Procedures
CAUTION:
Improper jump starting procedures can cause an explosion resulting in
personal injury.
Sparks near batteries can cause explosions.
Do not allow jump cable ends to touch each other or the machine.
Battery acid can cause personal injury if it contacts skin or eyes.
Always wear eye protection when jump starting a machine.
Always connect battery positive (+) to battery positive (+) and battery
negative (-) to ground on the machine. Make the final ground connec-
tion away from the battery.
Allowing the two machines to touch during jump starting can cause
damage to bearings and electrical circuits.
This machine has a 12 volt starting system. Use the same voltage (12
volts) for jump starting. Use of higher voltage can damage the electri-
cal system.
Never charge a frozen battery.
Fitting
Size
Thread Size
(NPT)
Turns
1
1.Turns past finger tight
-2 1/8-27 2–3
-4 1/8-27 2–3
-6 1/4-18 1.5–3
-8 3/8-18 2–3
-10 1/2-14 2–3
-12 3/4-14 2–3
-16 1-11.5 1.5–2.5
-20 1 1/4-11.5 1.5–2.5
-24 1 1/2-11.5 1.5–2.5