Service Manual User guide

Boom and Transfer
6-122
31200079
Fig. 6-125: Boom Elevation Proximity Switch Wiring
6. (Ref. Fig. 6-125) Remove boom elevation proximity switch as follows:
a. Disconnect connection wire from boom proximity switch.
b. Disconnect connection wire from wiring harness.
c. Remove all wire ties that secure the wiring harness to hydraulic
tubes and hoses so that it is completely separated from the transfer
carriage.
Fig. 6-126: Boom Cover Installation
7. (Ref. Fig. 6-126) Remove the boom cover on models with 3-section
booms (see Step a) or 4-section booms (see Step b).
a. Remove four (4) each nuts (Item 3), lockwashers (Item 1), and
flatwashers (Item 2) securing boom cover (Item 4) to boom.
Remove boom cover.
J1149
Wiring Harness
Connection
Proximity
Switch
Wire
J1169
3-Section Boom 4-Section Boom
# Description
1 Lockwasher
2 Flatwasher
# Description
3Nut
4Boom Cover
3
1
2
4
3
4
1
2