LUKO Dehumidifier User Manual Model No.: OL-R180P Please read this user manual before operating and save for future reference. You've been covered with a 1-year free warranty offered by LUKO which is automatically valid from the date of purchase. To extended the warranty to 2 years or for any questions or concerns, please email LUKO at support@oulungroup.
CONTENTS SAFETY INFORMATION...........................................................................................1 PRODUCT SPECIFICATIONS................................................................................. 2 FEATURES.................................................................................................................. 3 PARTS IDENTIFICATION......................................................................................... 4 OPERATION INSTRUACTIONS..........................
SAFETY INFORMATION • Install the dehumidifier on flat surface to minimize vibration and or noise. • Inspect the power cord before use. Never operate the dehumidifier when the power cord or plug is damaged. • Insert the three-prong plug on the power cord into a matching electrically grounded outlet (115V/ 60 Hz, 15 A at least). Do not use an adapter. Never cut off the third prong. Do not use an extension cord. • Do not operate the dehumidifier in standing water. Keep motor and wiring dry.
PRODUCT SPECIFICATIONS LUKO Dehumidifier Model No. OL-R180P Power Source AC 110-120V, 60 Hz (80°F, RH 60%) (86°F, RH 80%) (90°F, RH 90%) Input Power 740 W Input Current 6.9 A Moisture Removal 90 Pints/Day Input Power 900 W Input Current 8.4 A Moisture Removal 145 Pints/Day Input Power 1010W Input Current 9.2A Moisture Removal 180 Pints/Day BCSC 15 A Motor Compressor RLA:7.3A; LRA:36.4A Refrigerant R410a (19.8 oz.) High Pressure 522 PSIG (3.6 MPa) Low Pressure 240 PSIG (1.
FEATURES * Compact size with high efficiency, designed for crawlspaces * High Dehumidifying Capacity for commercial & industrial use * Straightforward Control Panel for easy operation * Built-in Pump for convenient drainage * Rotational Molded Housing for tough job * Compact Size and Fold-able Handle for space-saving transportation and storage * Hot Gas Valve System for fast defrost and low temperature operation * Washable Air Filter with Aluminum Frame * Easy to Assemble /Disassemble Housing for quick acce
PARTS IDENTIFICATION NOTE: • Do NOT obstruct the air inlet and/or outlet while the dehumidifier is running. • Apart from the 17 ft long drain hose for pump drainage, the package also includes a 3.3 ft larger hose which is used for emergency drainage in the event of pump failure.
OPERATION INSTRUACTIONS 1. Position Your Dehumidifier IMPORTANT Transporting or storing the dehumidifier in a vertical position is not recommended. When the dehumidifier is placed in a vertical position, the oil from the compressor can flow into the refrigerant coils and reduce the ability of the dehumidifier to function and possibly damage the dehumidifier. If the dehumidifier has been placed in a vertical position, set it horizontally and let it sit for at least 24 hours before plugging it in.
• If you use a bucket or other container for water collection, check it regularly to prevent overflows. • The drain hose for the water pump can drain up to 15ft vertically. More than 15ft may cause water back up to the pump resulting in leakage. • When turning off the dehumidifier, please take the hose out from the water collection container to avoid the water back-flow causes water leakage. • To remove the drain hose from the outlet, press and hold the buckle on the connect fitting and pull the hose out.
to turn the dehumidifier on. The readout on the display screen will light up and the dehumidifier will run in continuous dehumidify mode. - To Turn the Dehumidifier OFF: Press the POWER button again to turn the dehumidifier off. The compressor will turn off right after you pressed the POWER button, but the fan will not stop until 1-2 minutes later. PURGE Button: Press and hold the PURGE button for 3-5 seconds to manually empty water from the pump reservoir.
timer at the same time. - The Delay Start/Stop Feature will work until the dehumidifier either starts or stops. - The TIMER will ONLY function one time instead of cycling the dehumidifier on or off indefinitely. ✱To check the Actual Room Temperature: Press and hold the TIMER button for 3-5 seconds, the display screen will display the room temperature for 5 seconds and then turn to display the actual room humidity reading.
humidity reading. When you set timer, it displays the timer setting value. 5. Smart Functions Auto Drainage Thanks to the built-in pump, the dehumidifier will drain the condensation water automatically. Wait 3 Minutes before Resuming Operation To avoid any damage to the dehumidifier, the dehumidifier will not start operation following a complete cycle until after 3 minutes. Operation will automatically start after 3 minutes.
MAINTENANCE Ensure the dehumidifier is turned OFF and the plug is removed from the power socket before cleaning or maintenance is carried out. 1. Cleaning the Dehumidifier Clean the dehumidifier house with a soft damp cloth. Do not submerge or place water on the dehumidifier or control panel. Water may damage the electronic components of the dehumidifier. Do not use chemical solvents such as benzene, alcohol, gasoline or other heavy-duty cleaners. The surface may become damaged or deformed. 2.
TROUBLE SHOOTING GUIDE Problem Dehumidifier does not operate Dehumidifier collects little water dehumidifier operating, but room not dry Error Code E1 E2 Possible Cause Solution No power to dehumidifier Connect plug to power socket Switch not turned on Switch on E4 error is displayed Check drainage flow Insufficient working time Allow more working time Filter is blocked Clean filter Low ambient temperature Heat up the room Condensate hose is blocked Check hose for restrictions Doors and w
WARRANTY INFORMATION LUKO offers a 1-year free warranty on all of our products, with original proof of purchase and where a defect has arisen, wholly or substantially, as a result of faulty manufacture, parts or workmanship during the warranty period.
13