Instruction Manual

34
Visual inspection
Hydraulic units
All hydraulic connections are still tightened
General tightness, no leakage (sweated oils do not have any inÀ uence on the function)
Obvious damage on the motor/engine, connecting blocks or frame
Obvious damage to the hydraulic system and/or gasoline tank,
Side panels present and securely ¿ tted
Type plate, all activation plates, signs, identi¿ cation marks and warning labels are present
and legible
All covers (e.g. exhaust deÀ ector) are present and undamaged
All heat protection mats on the reservoirs are present and undamaged,
Minimum gap of 10 mm between the reservoirs and hot motor/engine components
Liquid levels are within the speci¿ ed tolerances
Starters are in proper working order and undamaged
Electric cables are fully functional and undamaged
Electric starter battery is fully functional and undamaged
Couplings must be easy to couple
Dust protection caps must be available
All necessary accessories (such as sparking plugs, plug spanner and fuel canister) must
be present.
Toolholder (if available) is undamaged and fully functional
Carrying handles (if available) are undamaged and fully functional
10.2 Hydraulic units with combustion engine
Operating period per day Functional check
up to 1 hour 1 x every year
up to 8 hours 1 x per quarter
up to 24 hours 1 x per month
A functional check should be performed in addition to these intervals if:
- the unit makes suspicious noises,
- there are grounds for suspecting that the unit has sustained internal damage.
Should either of the above occur several times within a month or the maximum pressure
is not reached during the functional check, contact LUKAS customer service immediately.
See the chapter "Troubleshooting" for contact details.
10.1.2 Functional check