12.4 Operating and storage temperature ranges
Operating temperature [°C] / [°F] -20 +55 -4 +131
Ambient temperature
(device in operation)
[°C] /
[°F] -25 +45 -13 +113
Storage temperature
(device not in operation)
[°C] /
[°F] -30 +60 -22 +140
12.5 Oscillation / vibration
The total oscillation value / vibration value to which the upper limbs are exposed, is below
2.5 m/s².
12.2 Noise emissions (based on the EN ISO 3744 standard)
Used power source Lithium-ion battery Power supply
Idling (measured at
a distance of 1 m)
[dB(A)] 54 54
Full load
(measured at a
distance of 1 m)
[dB(A)] 71 71
Idling (measured at
a distance of 4 m)
[dB(A)] 53 53
Full load
(measured at a
distance of 4 m)
[dB(A)] 67 67
Mineral oil DIN ISO 6743-4 for LUKAS hydraulic equipment and others
Oil temperature range Oil code Viscosity rating Remarks
A -20 .... +55°C HM 10 VG 10
Oil temperature range Oil code Viscosity rating Remarks
A
-4.0 .... +131°F HM 10 VG 10
recommended viscosity range: 10...200 mm²/s (10…200 cSt.)
Supplied with HM 10 DIN ISO 6743-4.
CAUTION!
Before you use hydraulic uids from a different manufacturer, you must contact
LUKAS or an authorised dealer.
12.3 Hydraulic uid recommendation