Fault Check Cause Solution
Connected rescue
device does not
reach its speci c
performance data
Maximum permitted
operating pressure of
the pump is not reached
Have repaired by
authorised service
facility, authorised
dealer or directly by
LUKAS
Connected unit
defective
Recti cation see
operating instructions of
the connected unit
During function test:
A pressure gauge
installed between the
rescue equipment
and the hydraulic
power pack does
not indicate the
maximum operating
pressure of the
equipment.
Check the details
of the rescue
device
The operating pressure
of the connected
rescue device is locked
internally
No repair or fault
recti cation required
Connected rescue
device is defective
Recti cation see
operating instructions of
the connected unit
Hydraulic unit defective Have repaired by
authorised service
facility, authorised
dealer or directly by
LUKAS
Maximum pressure
not achieved
Mono-coupling on
connection hose is
defective
Replace connection
hose
Hydraulic unit defective Have repaired by
authorised service
facility, authorised
dealer or directly by
LUKAS