29
Fault Check Cause Solution
The connected
rescue equipment
does not move on
activation of the
valve, or moves
only very slowly or
unevenly.
Connect a
different unit and
check whether
it works when
actuated
The previously
connected unit is
defective.
Recti cation see
operating instructions of
the connected unit
Air in the hydraulic
supply
Vent the hydraulic
system.
Mono-coupling on
connection hose is
defective
Replace connection
hose
Mono-coupling (female)
defective
Replace mono-coupling
(female)
P600OE defective Shut down immediately
and have repaired by
authorised dealer, motor
/ engine manufacturer
or directly by LUKAS
Leaks from pump
body itself
P600OE defective Shut down immediately
and have repaired by
authorised service
facility, authorised
dealer or directly by
LUKAS
Connected rescue
device does not
reach its nal
position
Check hydraulic
uid volume in
hydraulic reservoir
Insuf cient uid in the
hydraulic reservoir
Top up hydraulic uid
to the maximum lling
level
Important! Before
topping up the rescue
equipment, return to
the base position!
Usable hydraulic uid
volume of the unit is
insuf cient
Use a different rescue
device with a demand
quantity below the
maximum usable
quantity of the unit