Inspections to be carried out:
Visual inspection
No visible damage to the housing,
General tightness (leaks),
ON/OFF switch in proper working order, undamaged
Couplings must be easy to couple,
Dust protection caps must be present
Labels completely existent and legibly,
Illumination of main switch, work area and tank illumination fully functional.
Battery and power supply
• Casing undamaged,
Electrical contact surfaces clean and undamaged
• Cable undamaged
Battery(-ies) fully charged (when used)
Charging state display of lithium/ion battery(-ies) fully functional
Functional check
no suspicious noises,
tests at maximum load. When the maximum pressure is achieved, the pump switches
to the ECO mode after a short time. As soon as the pressure drops slightly, the pump
automatically switches back to the working mode.
(Recommendation: use the LUKAS test kit, including testing instructions, for the func-
tion test).
If the noises and suspicions referred to above arise several times in a month, or if maximum
pressure cannot be achieved during the function test, you need to contact LUKAS customer
service immediately. The contact details are given in the Chapter "Fault analysis".