Instruction Manual

27
11.3 Hydraulicuidchangeoraddinghydraulicuid
11.4 Care
The hydraulic uid should be changed if dirty at least once a year. When the hand pump is
operated in an especially dusty environment, we recommend changing the uid at least once
every half year.
ATTENTION!
Add hydraulic uid only if the hand pump is disconnected from the lines or the
equipment operated with the pump is hydraulically depressurised. Otherwise,
after lling the entire hydraulic system could contain more hydraulic uid than
the tank can hold.
Procedure:
1. Open the bleed/ll cap on the tank.
2. Add hydraulic uid until the uid level comes up to 1-2 cm below the top edge of the oil
tank.
3. Bleed the hand pump as described in the chapter "bleeding the pump".
4. Check the uid level again and close the tank again at the correct uid level with the
vent/ll cap on the tank. Should the tank no longer be sufciently full after bleeding, start
the ll procedure again at item 2.
NOTE:
Should the uid level in the tank still not be reached after repeated relling (during
maintenance), we recommend searching for leaks in the hydraulic system.
If possible, do not store the hand pump in a damp or extremely dusty environment in order
to ensure a long service life. If this is unavoidable, you should perform more frequent
maintenance and/or shield the pump from these effects if possible.
Regularly coat all metal parts with oil to prevent any corrosion.