Instruction Manual

14
6.4 2-way distribution valve
NOTE:
To mount the 2-way distribution valve, rst the base plate without closing
screws, ttings and couplings has to be mounted.
1. Put the sealing rings and the 2-way
distribution valve onto the pump head, so
that the boreholes “T” and “P” of the 2-way
distribution valve matches with the ports of
the base plate / pump head.
Take care, that the surfaces are clean and
dust-free.
2. Put the 4 screws into the designated
boreholes and tighten them with a torque
of 32 Nm.
3. When you are connecting the hose assemblies directly to the hand pump, you will have
to mount appropriate designated couplings, ttings or closing screws to the ports “P” and
“T”. (tightening torque M
A
= 40 Nm)
ATTENTION!
After the end of the assembly close all hydraulic lines by using closing screws
and/or dust protection caps, to prevent the hand pump from impurities.