13.1.2 Noise emissions (in accordance with EN ISO 3744):
type PC-6 GC-6 DC-6
ref.no. 840729316 840729317 840729319
idle running
(measuring distance: 1m)
[dB(A)] 73 85 93
full load
(measuring distance: 1m)
[dB(A)] 78 89 93,7
idle running
(measuring distance: 5m)
[dB(A)] 65 82 82
full load
(measuring distance: 5m)
[dB(A)] 67 85 83,5
13.2 Recommendedhydraulicuid
13.3 Hoses
13.4 Operating temperature and storage temperature ranges
See separate operating instructions for the hydraulic hoses.
Mineral oil DIN ISO 6743-4 for LUKAS hydraulic equipment and others
Oil temperature range Oil code Viscosity rating Remarks
A -24 .... +30°C HL 5 VG 5
B -18 .... +50°C HM 10 VG 10
C -8 .... +75°C HM 22 VG 22
D +5 .... +80°C HM 32 VG 32
E -8 .... +70°C HF-E15 VG 15 Bio-oil
Oil temperature range Oil code Viscosity rating Remarks
A -11.2 .... +86°F HL 5 VG 5
B -0.4 .... +122°F HM 10 VG 10
C +17.6 .... +167°F HM 22 VG 22
D +41.0 .... +176°F HM 32 VG 32
E +17.6 .... +158°F HF-E15 VG 15 Bio-oil
recommended viscosity range: 10...200 mm²/s (10…200 cSt.)
Supplied with HM 22 DIN ISO 6743-4.
Ambient temperature (device in operation) [°C] -20 … +55
Storage temperature (device not in operation) [°C] -30 … +60