Manual
34
Technical data13.
As all values are subject to tolerances, there may be minor differences between the data
achieved by your equipment and the data specied in the following table.
13.1 Hydraulic power pack
1)
HP = High pressure
2)
NP = Low pressure
3)
1 MPa = 10 bar
13.1.1 Basic data
type PC-6
ref.no. 840729316
dimensions
l x w x h
[mm] 560 x 540 x 695
[in.] 22.04 x 21.26 x 27.36
motor type
electric motor
400V / 50Hz
motor power
[kW] 2,2
[HP] 2.95
rotation speed
[min
-1
]
2850
[rpm.]
max. operating
pressure (HP)
1)
[MPa]
3)
53
[psi.] 7,687
max. operating
pressure(LP)
2)
[MPa]
3)
23
[psi.] 3,336
owrate
(HP)
1)
[l/min] 2,3
[gal.-US/min] 0.61
owrate
(LP)
2)
[l/min] 5,3
[gal.-US/min] 1.40
max.ll-up
quantity
[l] 42
[gal.-US] 11.10
max. useable
quantity
[l] 35
[gal.-US] 9.25
weight (incl. all
max.uidll-up
quantities)
[kg] 61
[lbs.] 134.5
ambient
temperature
[°C] - 20 … + 55
[°F] - 4 … + 131
max. options to connect devices 1