Manual

16
An electric starter is available from the LUKAS range of accessories for some units.
(Forspecicdetails,pleaseconsulttheLUKASrangeofaccessoriesorcontactyourLUKAS
dealer).
On these units, after checking the uid levels, proceed as follows:
1. Switch to "START ENGINE"
2. Turn the ignition key clockwise.
Charge the accumulator of the electric starter:
1. Switch to "CHARGE BATTERY"
2. Connect the supplied charger to the mounted socket.
8.1.2 Electric motors
Before starting the electric motors, check that all electrical connections and cables are in
proper order. First of all, connect the power cable (for motors with power supply) to the
supply socket.
The motor is started by turning the ON/OFF switch to the ON position.
CAUTION!
Electric motors need a brief, very high starting current. When using a generator,
you should therefore check to see that it can also supply the relevant current
strength.
Formotorsratedupto1.5kW,thepowersupplymustbeprotectedbyafusewith
aminimumratingof25A(slowblow).Formotorsratedover1.5kW,theminimum
fuseratingis30A(slowblow).
Astheinformationabovemayvarydependingonindividualcircumstancesand
on thetype of motor used, you should always consultyour dealer or LUKAS
directly in case of doubt.
8.2 Stopping the motors
8.2.1 Gasoline / petrol and diesel engines
The gasoline / petrol and diesel engines stop automatically when the fuel tank is empty.
Should they stop moving beforehand, the following procedure is required:
Procedure for stopping Briggs & Stratton engines:
1. Move the lever from switch position C to switch
position A
2. When the engine has come to a standstill, close the
fuel tap.
Procedure for stopping Intek engines:
1. Move the top lever from switching position F to
switching position E
Lever at top
Lever at bottom
EF
G H
ABC