User's Manual
uBoard Installation Guide (V4.1)
19 |
P a g e
If the blue led light on the station is not on, please check the USB cable is
properly connected to the station and the computer.
[wireless model] wait till both “blinking blue light” on the station and the active-
link are permanently on. It means Bluetooth connection is successfully
established.
uBoard wireless model is using the Bluetooth technology and therefore it
doesn’t require USB cable connection between the station and the computer.
But the Active-link should be always connected to the computer because
uBoard tries auto-pairing between uBoard station and the Active-link. Auto-
pairing technology enables Bluetooth to be auto-connected like RF wireless
without requiring user intervention in the case even the pairing was broken.
[wireless model] If the user wants to use USB cable communication between
the station and the computer, connect USB cable to the computer directly
without using the Active link as the wireless communication has higher priority
than USB cable communication when the Active-link is connected to the
computer.
Note :
When uBoard is not configured by the computer, uBoard will not work properly.
So when the connection is failed, check whether it is properly configured by
Windows OS. [refer to 3.4 Option for uBoard setup]
④ Press ‘Calibration’ button on the station.
When you press ‘calibrate’ button, uBoard displays calibration as depicted
below. Then touch the center of the circle with the digital pen. As uBoard uses
9 points calibration to recognize the screen size, it requires repeating this step
9 times as guided by the system.
After calibration is done successfully, uBoard returns its control to the MINT
Interactive if ‘Launch’ is selected in step . But when SW installed to the
computer by selecting ‘Install’ option, it returns to the window mode after
successful calibration. In this
case, click ‘MINT Interactive’
on the desktop windows to
launch annotation SW.
[ Calibration Window ]