Lufft OPUS20 LAN-Datalogger Future Inside a pa passsiio on ffo or pr prec ciissio ion · p pa ass ssio on p po our u la prréc éciisssio ion io n · pa pasi sió si ón po ón orr la p prrec ecissió ión · pa pass ssio sio i ne ne perr la p prre ec ciis cis sione ione io e·a www.lufft.
The world’s toughest legal guidelines: 21 CFR Part 11 (electronic records). The pharmaceutical industry trusts in Lufft.
Today’s industrial data acquisition generally takes place in real time. The conditions and process environments of measured values regarding room climate change slowly, but are, nevertheless, permanent. Therefore, modern data recording systems that are implemented in this industry have to be reliable like Lufft products.
Measurement Lufft OPUS20 Functions Functions Power supply battery Power supply USB Power supply LAN (POE) Measured data storage Typical battery life LC-display One-button operation 1-point calibration by user/operator °C/°F switchable Optical/acoustical alarm Date/time Records Min/Max/Avg.
Lufft OPUS20 THI Temperature and rel. Humidity Lufft OPUS20 Temperature and Relative Humidity Measurement Order-No. Lufft OPUS20 Temperature / rel. Humidity (neutral without Lufft-Logo 8120.00N) 8120.00 Lufft OPUS20 Temperature / rel. Humidity PoE (neutral without Lufft-Logo 8120.01N) 8120.
Measurement Finally available: Lufft’s precise weather station for interior applications – an essential data collector for all calibration laboratories. Lufft OPUS20 THIP Temperature, Rel. Humidity, Air Pressure Lufft OPUS20 THIP Temperature, Relative Humidity, Air Pressure Temperature Rel. humidity Air pressure Accessories For high-precision air pressure measurements 6 Order-No. Lufft OPUS20 THIP Temperature / Rel. Humidity / Air Pressure 8120.10 (neutral without Lufft-Logo 8120.
Lufft OPUS20 TCO Temperature, Rel. Humidity, CO2 Lufft OPUS20 TCO / Temperature / Relative Humidity / CO2 Measurement Order-No. Lufft OPUS20 TCO / Temperature / Rel. Humidity / CO2 (neutral without Lufft-Logo 8120.20N) 8120.20 Lufft OPUS20 TCO / Temperature / Rel. Humidity / CO2 POE 8120.21 (neutral without Lufft-Logo 8120.
Representation and Evaluation software
SmartGraph3 Software With SmartGraph3 the gathering of measured data is simple and as intuitive as possible: ■ An OPUS20 datalogger is automatically recognised and added as a “network device”. ■ In addition to its data-readout function, the software possesses a recording mode that enables parallel recording to be displayed on the computer. ■ The data from any desired number of OPUS20 devices can be read out simultaneously. ■ The zoom function allows for quick analysis of critical time periods.
Measurement Highly Sensitive Measure m
The triple point of water (balance of all 3 physical states solid, liquid and gas) is used to represent the International Temperature Scale and for the highest precision of temperature measurements in the milli-Kelvin range. Measuring is not just measuring. Each application and application area requires the ideal sensor. Apart from this, it is imperative in the pharmaceutical production and food industry that the hundreds of guidelines in place are adhered to and a multitude of inspections conducted.
Measurement Temperature/Humidity Sensors Temperature/ Humidity Sensor Order-No. Temperature/ Humidity Sensor Temperature/ Humidity Sensor (stainless steel sintered cap) for clean rooms Temperature Air temperature measuring range –40 … 80 °C Accuracy ±0.1°C at 20°C ±0.3°C at -10°C...+50°C Otherwise <=0.5°C Humidity Rel. humidity measuring range 0 …100% Accuracy ±2% r.H. (0...90% r.H.) ±3% r.H. (0...100% r.H.
Air Temperature/CO2 Measurement Air Temperature Order-No. PT100 Temperature Sensor with 10m cable PT100 Temperature Sensor with 50m cable Temperature Principle Measuring range Accuracy 8160.TF 8160.TF50 PT100 –50 … 150 ° C Class A Surface Temperature Order-No. PT100 Temperature Sensor with 10m cable PT100 Temperature Sensor with 50m cable Temperature Principle Measuring range Accuracy 8160.TFLT 8160.TFLT50 PT100 –100 … 100 ° C Class A CO2 Order-No.
Measurement Air Flow Air flow Order No. Well-priced air flow transmitter for heating, cooling and ventilation applications Duct mounting with display 5613.00 Duct mounting without display Remote sensor without display Remote sensor with display Principle Measuring range Accuracy Heated thin film layer 0 ... 20m/s ±0.2m/s + 3% of measured value (at 20°C, 45% r.H., 1,013 Pa) Strömung Order No.
Differential Pressure Differential Pressure messen me ess ssen en Measurement Order-No. Well-priced and reliable differential pressure sensor for installation in the control panel, with automatic zero point traceability Principle Micro mechanical Measuring range - 100 Pa... +100 Pa Accuracy 0.8 % of measured value Output 4...20mA Power supply 12V DC Option: Measuring range 0...100Pa 2191.100B 2191.100 Particle Particle Counter (Pharmaceutical) Order-No. Counts particles in the 0.
Storage and Transfer Relliiab Reliable blle S a T 16
Not all offered solutions contain a temporary storage device. Lufft: with its experience the more intelligent solution. The system is simple; Lufft Data Loggers store and transfer data. One could also say that it is simply ingenious! From a technical point of view, it is optimally engineered and highly reliable.
Measurement With up to 10 external channels/sensors per OPUS20E. The OPUS20E offers the highest flexibility and is excellent value for money. It allowes the connection of up to 4 external temperature and relative humidity sensors, as well as 2 further analogue sensors. Intelligent BUS sensors can be integrated via the OPUS20E’s RS485 interface (e.g. particle counter).
Lufft OPUS20E Configurations Examples Lufft OPUS20E for External Sensors Technical data Thermocouple J Measurement range Order-No. PT100 Accessories (see page 12) Resolution +/- 1°C +/- 0.5% of measured value at -200°C ... 0°C +/- 1°C +/- 0.2% of measured value at 0°C ... 1,200°C < 0.2°C Measurement range -50°C ... 1,700°C Accuracy Resolution +/- 1°C +/- 0.5% of measured value at -50°C ... 0°C +/- 1°C +/- 0.2% of measured value at 0°C ... 1,700°C < 0.2°C Measurement range -200°C ...
Representation and Evaluation No place for coincidence. Anyone who records data in real time should not be satisfied with an “off the rack” solution only. Lufft has never done this and never will. We have even put a lot of thought into the representation and evaluation of your measured data, and have developed special software that offers users numerous advantages and possibilities. Data errors can be reduced to a minimum by means of clear processing and representation.
Software MCPS7 for Lufft OPUS20 Representation and Evaluation Software MCPS7 Software for OPUS20 MCPS Option Description Industrial-Standard Industrial-Professional Order-No. 8040.I1 Order-No. 8040.I2 PharmaceuticalStandard Order-No. 8040.P1 PharmaceuticalProfessional Order-No. 8040.
Qualification and Calibration Competent Qualifica Q a
Qualification can only be done by a qualified and experienced professionals. We ensure that you have excellent measuring technology experts at your side for such a task. Imprecise measurements can have expensive repercussions. Therefore, Lufft products are tested according to the motto “To trust is good, to control is better”.
Alarm Accurately Timed
No matter what your organigram looks like for this important task, our alarm system can be implemented. Lufft cannot afford any flaws, and especially not when companies have to react as quickly as possible. Pharmaceutical- and clean room applications are excellent examples of this, where possible deviations require immediate action. For this reason Lufft has a special alarm concept to safeguard the measurement process.
Alarm Signal Tower Bestell-Nr. Lufft Signal Tower with LED beacons Wall mounting bracket 8161.SIGNAL Base mounting Dimensions Housing design Max. burden (resistor) Display Weight Storage temperature Protection type Power supply Connecting system Power consumption active Power consumption stand-by Max. operating temperature Max rel. humidity Accessories 26 Alarm 8162.SIGNAL 160 x 50 x 45 mm Plastic 0.5 A/30 V: 500,000 cycles 0.
Measuring is not just measuring. Each application and application area requires the ideal sensor. Apart from this, it is imperative in the pharmaceutical production and food industry that the hundreds of guidelines in place are adhered to and a multitude of inspections conducted. Only then can long-lasting international standards be guaranteed. Lufft can help you fulfil all such criteria and find the right product.
Wherever measured data is transferred by means of LAN within industry, Lufft‘s OPUS20 datalogger family can be ideally applied everywhere! With OPUS20, each ethernet cabable datalogger can be provided with an IP address even in remote monitoring networks, where many dataloggers are in operation.