10. Technical Data
Technical Data THI THIP TCO
Air temperature
Principle NTC
Measuring range -20 °C to + 50 °C
Accuracy ± 0.3 °C (0…40 °C), otherwise 0.5 °C
Display resolution 0.1 °C
Rel. humidity
Principle capacitive
Measuring range 10 to 95 % RH
Accuracy ±2 % RH
Display resolution 0.5 % RH
Air pressure
Measuring range 3001,300 hPa abs.
Accuracy
7001,100 mbar
at 25 °C ±0.5 hPa
Display resolution 0.1 hPa
CO concentration
Principle NDIR
Measuring range 0 5,000 ppm
Accuracy
±50 ppm +3 measuring
value at 20 °C
and 1,013 mbar
Display resolution 1 ppm
long-time stable 20 ppm / a
Memory organisation
Sampling interval 10 / 30 s, 1 / 10 / 12 / 15 / 30 min, 1 / 3 / 6 / 12 / 24 h
Memory interval 1 / 10 / 12 / 15 / 30 min, 1 / 3 / 6 / 12 / 24 h
Data memory 16 MB, 3,200,000 measuring values
Data logging up to 20 measuring channels parallel
Features and
dimensions
LCD display W 90 x H 64 mm
Casing Synthetic material
Dimensions L 166 x W 32 x H 78 mm
Weight approx. 250 g
Interface USB, LAN
Power supply
internal 4 x LR6 AA mignon batteries, battery life > 1 year
external USB, LAN (PoE model)
Permissible operational
environmental conditions
Air temperature -20 °C to +50 °C
rel. humidity 0 to 95 % RH, < 20 g / m³ (non-condensing)
Height 10,000 m above MSL
Scope of delivery
Standard
Data logger, CD ROM with SmartGraph 3 PC software
for graphic and numerical display of measurement assessments
and operating instructions, USB cable, batteries
Optional PoE model