 DSX-1 to Network Time Slot Assignment Screen Example (Page 1)
main/config/tslot_assign/dsx  9124
Device Name: Node A  5/26/1999 23:32
 DSX-1 TO NETWORK 1
 ASSIGNMENTS Page 1 of 2
   N01 N02   N03 N04   N05   N06  N07   N08
D01-1/01 
 D01-1/02 D01-1/03 D01-1/04   Assigned Assigned Assigned Assigned
   N09 N10   N11 N12   N13   N14  N15   N16
D01-1/09 
 D01-1/01  Available Available Available Available Available Available
   N17 N118   N19 N20   N21   N22  N23   N24
Available
 Available Available Available Available Available Available Available
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menu M
ainMenu Exit
 S
ave  PgDn PgUp  ClearAll FrAssign
Page 2 of 2 is for defining signaling assignments and trunk conditioning for each
DSX-1 interface time slot. See DSX-1 Signaling Assignments and Trunk
Conditioning for an example of this screen.
For easy movement between screens, select the F
rAssign function key to go
directly to the Frame Relay Network Assignments screen.
Time Slot Assignment Rules:
H Valid Network time slots are either Available or contain a DSX-1 time slot
assignment.
H Valid DSX-1 time slots are those that are unassigned, including the currently
assigned time slot.
H Order of display is as follows:
— Available is the first selection.
— Then, from the lowest DSX-1 interface to the highest DSX-1 interface.
— Then the lowest available time slot number to the highest available time
slot number.
For example, if the cursor is on a field with the Available value under
assigned time slot Ntt, pressing the spacebar causes this field’s values to
cycle through all valid DSX-1 time slots, starting with Ds-p/yy, assuming it is
unassigned. If Ds-p/tt is already assigned, the next valid time slot in the order
described above is displayed.