Window User Manual
Troubleshooting
 6-22
9124-A2-LB20-00
March 2000
Physical Tests
A FrameSaver 9124 unit’s physical tests screen for the network interface is
shown below.
Main Menu →Test →[Network Physical Tests/Data Port Physical Tests/
DSX-1 Physical Tests]
 Physical Tests Screen Example
main/test/network  9124-II
Device Name: Node A  5/26/1999 23:32
 NETWORK 1
 PHYSICAL TESTS
Test  Command Status Results
 Local Loopbacks
Line Loopback: Start  Inactive 0:00:00
Payload Loopback: Start  Inactive 0:00:00
Repeater Loopback: Start  Inactive 0:00:00
 Remote Loopbacks
Send Line Loopback: Down
Send  Inactive 0:00:00
 Pattern Tests
Send: user-defined
0a0a Stop  Active 0:00:00 - Errors 99999+
Monitor: user-defined
0a0a Stop  Active 0:00:00 - Errors 99999+
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menu M
ainMenu Exit
 I
njectErr ResetMon
The ResetMon function key at the bottom of the screen only appears when a
Monitor 511 test pattern is Active. Select R
esetMon to reset the monitor pattern
error counter.
CAUTION:
You should not run these tests with frame relay equipment attached;
you must disconnect the frame relay equipment and use external test
equipment.