Window User Manual
Operation and Maintenance
 5-19
9124-A2-LB20-00
March 2000
Network LMI-Reported DLCIs Status
Network LMI-reported DLCI statuses are selected from the Status menu.
Main Menu →Status →LMI Reported DLCIs
The LMI Reported DLCIs screen displays the status and CIR (if supported by the
switch) for each DLCI, whether the DLCI is configured or not.
LMI-Reported DLCIs Status Screen Example
main/status/lmi_dlcis     9124-II
Device Name: Node A  05/26/1999 23:32
frame relay link
 LMI REPORTED DLCIs  Page 1 of 2
DLCI STATUS CIR (bps) DLCI STATUS CIR (bps)
 *  300  Active  16000  *  622 Active  32000
 *  305  Inactive  *  624 Active  32000
 *  400  Deleted  *  625 Deleted
 *  410  Inactive  *  713 Active  32000
   411  Inactive  *  822 Active  32000
   420  Inactive  32000  * 1002 Active  32000
   430  Active
   501  Inactive
   511  Active  256000
   520  Active  64000
 * – DLCI is configured on the Frame Relay Link.
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
ESC for previous menu M
ainMenu Exit
 R
efresh  PgUp PgDn NextLink PrevLink
An asterisk (*) next to the DLCI indicates that the DLCI has been configured for
the link.
DLCIs without an asterisk have not been configured in the unit. These DLCIs
pass through the unit transparently, without being monitored and with no
demultiplexing/multiplexing of management diagnostics or user data being
performed. Only DLCIs on the Net1-FR1 and Port-1 frame relay links appear on
this screen; nonconfigured DLCIs on other links are discarded.