Maintenance Object Repair Procedures 
Page 10-327CO-TRK (CO Trunk) 
10
2056 ABORT An error occurred while trying to obtain results from the TN771 circuit 
pack. 
1. Test the TN771 circuit packs.
2. If the test continues to abort escalate the problem.
FAIL Measured transmission performance was in the unacceptable range as 
administered on the trunk group form. Retrieve a measurement report via 
the list testcalls command. Make sure that ATMS thresholds are set 
properly on page 4 of the trunk group form. Besides the facility, test 
failures can be caused by faulty test lines or switch paths. If the 
measurements point to a facility problem, report the results to the trunk 
vendor.
8000 FAIL Measured transmission performance was in the marginal range as 
administered on the trunk group form. This generally means that the trunk 
is usable but has an undesirable amount of noise or loss. If the user does 
not report unacceptable effects, it may not be necessary to take any 
action. Retrieve a measurement report via the list testcalls command. 
Make sure that ATMS thresholds are set properly on page 4 of the trunk 
group form.
Table 10-106. TEST #844-848 Transmission Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page